2_FPGA_Modbus_1M_RAM
所属分类:其他
开发工具:Quartus II
文件大小:1647KB
下载次数:37
上传日期:2017-10-27 15:19:23
上 传 者:
Darren12
说明: 用 FPGA 编写的 MODBUS 协议通信
(Communication of MODBUS protocol written with FPGA)
文件列表:
2_FPGA_Modbus_1M_RAM (0, 2014-05-23)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus (0, 2014-05-23)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Modelsim (0, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus (0, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.asm.rpt (8882, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.done (26, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.dpf (239, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.fit.rpt (138071, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.fit.smsg (513, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.fit.summary (611, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.flow.rpt (11318, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.jdi (21, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.map.rpt (108065, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.map.smsg (17303, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.map.summary (471, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.merge.rpt (12611, 2013-05-20)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.pin (27423, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.pof (524474, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.qpf (1262, 2013-05-07)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.qsf (4437, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.qws (2603, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.sof (240775, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.tan.rpt (211631, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.tan.summary (2288, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\db (0, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\db\TOP_Module.db_info (137, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\db\TOP_Module.eco.cdb (161, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db (0, 2014-05-23)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions (0, 2014-05-23)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.autos_3e92b2e5d298f5cf757a393f7655ccd81.map.atm (424776, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.autos_3e92b2e5d298f5cf757a393f7655ccd81.map.hdbx (88280, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.autos_3e92b2e5d298f5cf757a393f7655ccd81.map.kpt (1926211, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.autos_3e92b2e5d298f5cf757a393f7655ccd81.map.logdb (4, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.atm (138526, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.dfp (33, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.hdbx (19508, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.kpt (341, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.logdb (4, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.rcf (53564, 2013-06-06)
... ...
------------------------------------------------------------------------------------
Modbus Poll V3.60b
Copyright (c) Witte Communications 2005. All rights reserved.
------------------------------------------------------------------------------------
IMPORTANT for win95 users:
-----------------------------
If the file ws2_32.dll is not found you have to
update your win95 with the service pack w95ws2setup.exe.
Download it from www.modbustools.com or www.microsoft.com
New features in version 3.60b
-----------------------------
- Precision format in float and double display changed.
- Memory leak problem with the OLE/Automation function
CreateRequest fixed.
- If slave device returned exception error = 0 it was
displayed as:
"Exception Error 128" instead of "Exception Error 0"
Note that 0 is not an expected error code according to
the Modbus specification.
- Excel example changed.
New features in version 3.60a
-----------------------------
- Text for TCP/IP Timeout information corrected.
- 4 minutes trial period extended to 10 minutes.
New features in version 3.6
-----------------------------
- TCP/IP 'Display communication' improved.
- 'Remove Echo' check box in connection setup added.
- Minor changes in help file.
- Connection information in status bar.
- Error Counters in display menu. (F11)
New features in version 3.5
-----------------------------
- Open/save workspace. File menu
- Always on top. View menu.
- Scan rate now up to 60000ms
- "Stop on error" in traffic view
- Modbus Transaction ID in TCP/IP is now unique
- The logging function logs errors as well
- Timing bug when logging multiple windows is fixed
Modbus Poll overview
-----------------------------
Modbus Poll is a powerful, easy to use, Modbus tool.
With Modbus Poll you can monitor and test your modbus
slave devices. Some of the features:
- Supports Modbus/TCP, RTU and ASCII modes.
- Test Center for modbus slave developers.
- OLE Automation for interfacing with Visual Basic
Excel etc. To interpret and show the modbus data
according to your specific requirements. E.g. edit
data in Excel and then send to your slave!
- Multiple windows for monitoring of multiple
slaves/data areas.
- Monitoring of serial traffic.
- Data logging to a text file readable by MS Excel.
- Multithreated for best performance.
- Print preview etc.
- 10 Display formats.
To change a value, simply double click.
System Requirements
-----------------------------
Minimal configuration:
* Pentium 133 or higher
* 32MB RAM
* 800x600 screen resolution
* Windows 95/***/ME/NT4/2000/XP
Preferred configuration:
* Pentium 200 or higher
* 32MB RAM
* 800x600 screen resolution
* Windows 95/***/ME/NT4/2000/XP
Order information
-----------------------------
Visit http://www.modbustools.com
Technical Support
Your feedback is very important for the further development
of Modbus Poll. For bug reports, comments, suggestions or
complaints, please find contact information at
http://www.modbustools.com
近期下载者: