2_FPGA_Modbus_1M_RAM

所属分类:其他
开发工具:Quartus II
文件大小:1647KB
下载次数:37
上传日期:2017-10-27 15:19:23
上 传 者Darren12
说明:  用 FPGA 编写的 MODBUS 协议通信
(Communication of MODBUS protocol written with FPGA)

文件列表:
2_FPGA_Modbus_1M_RAM (0, 2014-05-23)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus (0, 2014-05-23)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Modelsim (0, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus (0, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.asm.rpt (8882, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.done (26, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.dpf (239, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.fit.rpt (138071, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.fit.smsg (513, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.fit.summary (611, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.flow.rpt (11318, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.jdi (21, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.map.rpt (108065, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.map.smsg (17303, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.map.summary (471, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.merge.rpt (12611, 2013-05-20)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.pin (27423, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.pof (524474, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.qpf (1262, 2013-05-07)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.qsf (4437, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.qws (2603, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.sof (240775, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.tan.rpt (211631, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\TOP_Module.tan.summary (2288, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\db (0, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\db\TOP_Module.db_info (137, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\db\TOP_Module.eco.cdb (161, 2014-09-01)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db (0, 2014-05-23)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions (0, 2014-05-23)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.autos_3e92b2e5d298f5cf757a393f7655ccd81.map.atm (424776, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.autos_3e92b2e5d298f5cf757a393f7655ccd81.map.hdbx (88280, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.autos_3e92b2e5d298f5cf757a393f7655ccd81.map.kpt (1926211, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.autos_3e92b2e5d298f5cf757a393f7655ccd81.map.logdb (4, 2013-06-05)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.atm (138526, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.dfp (33, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.hdbx (19508, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.kpt (341, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.logdb (4, 2013-06-06)
2_FPGA_Modbus_1M_RAM\FPGA_Modbus\Quartus\incremental_db\compiled_partitions\TOP_Module.root_partition.cmp.rcf (53564, 2013-06-06)
... ...

------------------------------------------------------------------------------------ Modbus Poll V3.60b Copyright (c) Witte Communications 2005. All rights reserved. ------------------------------------------------------------------------------------ IMPORTANT for win95 users: ----------------------------- If the file ws2_32.dll is not found you have to update your win95 with the service pack w95ws2setup.exe. Download it from www.modbustools.com or www.microsoft.com New features in version 3.60b ----------------------------- - Precision format in float and double display changed. - Memory leak problem with the OLE/Automation function CreateRequest fixed. - If slave device returned exception error = 0 it was displayed as: "Exception Error 128" instead of "Exception Error 0" Note that 0 is not an expected error code according to the Modbus specification. - Excel example changed. New features in version 3.60a ----------------------------- - Text for TCP/IP Timeout information corrected. - 4 minutes trial period extended to 10 minutes. New features in version 3.6 ----------------------------- - TCP/IP 'Display communication' improved. - 'Remove Echo' check box in connection setup added. - Minor changes in help file. - Connection information in status bar. - Error Counters in display menu. (F11) New features in version 3.5 ----------------------------- - Open/save workspace. File menu - Always on top. View menu. - Scan rate now up to 60000ms - "Stop on error" in traffic view - Modbus Transaction ID in TCP/IP is now unique - The logging function logs errors as well - Timing bug when logging multiple windows is fixed Modbus Poll overview ----------------------------- Modbus Poll is a powerful, easy to use, Modbus tool. With Modbus Poll you can monitor and test your modbus slave devices. Some of the features: - Supports Modbus/TCP, RTU and ASCII modes. - Test Center for modbus slave developers. - OLE Automation for interfacing with Visual Basic Excel etc. To interpret and show the modbus data according to your specific requirements. E.g. edit data in Excel and then send to your slave! - Multiple windows for monitoring of multiple slaves/data areas. - Monitoring of serial traffic. - Data logging to a text file readable by MS Excel. - Multithreated for best performance. - Print preview etc. - 10 Display formats. To change a value, simply double click. System Requirements ----------------------------- Minimal configuration: * Pentium 133 or higher * 32MB RAM * 800x600 screen resolution * Windows 95/***/ME/NT4/2000/XP Preferred configuration: * Pentium 200 or higher * 32MB RAM * 800x600 screen resolution * Windows 95/***/ME/NT4/2000/XP Order information ----------------------------- Visit http://www.modbustools.com Technical Support Your feedback is very important for the further development of Modbus Poll. For bug reports, comments, suggestions or complaints, please find contact information at http://www.modbustools.com

近期下载者

相关文件


收藏者