Modbus Poll

所属分类:其他
开发工具:C/C++
文件大小:535KB
下载次数:5
上传日期:2019-05-03 09:55:59
上 传 者6525968
说明:  modbus 测试用的好工具,简单明了,自动生成modbus协议格式的报文
(modbus test tool,auto create modbus protocol.)

文件列表:
Modbus Poll\examples\excel\example.xls (38400, 2008-02-02)
Modbus Poll\examples\VB6\vbexample.frm (4032, 2008-02-02)
Modbus Poll\examples\VB6\vbexample.vbp (776, 2008-02-02)
Modbus Poll\examples\VB6\vbexample.vbw (53, 2008-02-02)
Modbus Poll\examples\VBNET\VBExample.resX (13206, 2008-02-02)
Modbus Poll\examples\VBNET\vbexample.sln (903, 2008-02-02)
Modbus Poll\examples\VBNET\VBExample.vb (12222, 2008-02-02)
Modbus Poll\examples\VBNET\vbexample.vbproj (4658, 2008-02-02)
Modbus Poll\examples\VBNET\vbexample.vbproj.user (1813, 2008-02-02)
Modbus Poll\license.txt (2747, 2008-02-02)
Modbus Poll\mbpoll.chm (216870, 2008-02-20)
Modbus Poll\mbpoll.exe (745472, 2008-02-20)
Modbus Poll\mbpoll.tlb (3560, 2008-02-20)
Modbus Poll\uninstall.exe (52033, 2017-08-19)
Modbus Poll\examples\excel (0, 2017-08-19)
Modbus Poll\examples\VB6 (0, 2017-08-19)
Modbus Poll\examples\VBNET (0, 2017-08-19)
Modbus Poll\examples (0, 2017-08-19)
Modbus Poll (0, 2017-08-19)

------------------------------------------------------------------------------------ Modbus Poll Copyright (c) 2002-2008. Witte Software. ------------------------------------------------------------------------------------ Getting started: ----------------------------- 1. Press F3 to setup a connection. 2. Press F8 to setup protocol definition. Example: You want to read 20 holding registers from address 40011 (10). - Slave ID = The ID of your device - Function = 03 Read Holding Registers - Address = 10 (Protocol address) - Quantity = 20 - Scan Rate = 1000 (Then it will poll for data every 1000ms) 3. To change a value just start typing Note: you can always press F1 for help. Warning: ----------------------------- The use of RTS controlled RS232/RS485 converters should be avoided if possible. It is difficult to determine the exact time when to switch off the transmitter with non real-time operating systems like Windows and Linux. If it is switched off to early characters might still sit in the FIFO or the transmit register of the UART and these characters will be lost. Hence the slave will not recognize the message. On the other hand if it is switched off too late then the slave's message is corrupted and the master will not recognize the message. Modbus Poll overview: ----------------------------- Modbus Poll is a powerful, easy to use, master simulating tool. Modbus Poll will run on all 32-bit Windows versions in use today - Windows 2000, XP and Vista. With Modbus Poll you can monitor and test your modbus slave devices. Some of the features: - Supports Modbus/TCP, RTU and ASCII modes. - Test Center for modbus slave developers. - OLE Automation for interfacing with Visual Basic Excel etc. To interpret and show the modbus data according to your specific requirements. E.g. edit data in Excel and then send to your slave! - Multiple windows for monitoring of multiple slaves/data areas. - Monitoring of serial traffic. - Data logging to a text file readable by MS Excel. - Multithreated for best performance. - Print preview etc. - 10 Display formats. Press F2 or double click to edit or just start typing a new value. Order information: ----------------------------- Visit http://www.modbustools.com Technical Support: ----------------------------- Your feedback is very important for the further development of Modbus Poll. For bug reports, comments, suggestions or complaints, please find contact information at http://www.modbustools.com

近期下载者

相关文件


收藏者