Modbus Poll
所属分类:其他
开发工具:C/C++
文件大小:535KB
下载次数:5
上传日期:2019-05-03 09:55:59
上 传 者:
6525968
说明: modbus 测试用的好工具,简单明了,自动生成modbus协议格式的报文
(modbus test tool,auto create modbus protocol.)
文件列表:
Modbus Poll\examples\excel\example.xls (38400, 2008-02-02)
Modbus Poll\examples\VB6\vbexample.frm (4032, 2008-02-02)
Modbus Poll\examples\VB6\vbexample.vbp (776, 2008-02-02)
Modbus Poll\examples\VB6\vbexample.vbw (53, 2008-02-02)
Modbus Poll\examples\VBNET\VBExample.resX (13206, 2008-02-02)
Modbus Poll\examples\VBNET\vbexample.sln (903, 2008-02-02)
Modbus Poll\examples\VBNET\VBExample.vb (12222, 2008-02-02)
Modbus Poll\examples\VBNET\vbexample.vbproj (4658, 2008-02-02)
Modbus Poll\examples\VBNET\vbexample.vbproj.user (1813, 2008-02-02)
Modbus Poll\license.txt (2747, 2008-02-02)
Modbus Poll\mbpoll.chm (216870, 2008-02-20)
Modbus Poll\mbpoll.exe (745472, 2008-02-20)
Modbus Poll\mbpoll.tlb (3560, 2008-02-20)
Modbus Poll\uninstall.exe (52033, 2017-08-19)
Modbus Poll\examples\excel (0, 2017-08-19)
Modbus Poll\examples\VB6 (0, 2017-08-19)
Modbus Poll\examples\VBNET (0, 2017-08-19)
Modbus Poll\examples (0, 2017-08-19)
Modbus Poll (0, 2017-08-19)
------------------------------------------------------------------------------------
Modbus Poll
Copyright (c) 2002-2008. Witte Software.
------------------------------------------------------------------------------------
Getting started:
-----------------------------
1. Press F3 to setup a connection.
2. Press F8 to setup protocol definition.
Example:
You want to read 20 holding registers from address 40011 (10).
- Slave ID = The ID of your device
- Function = 03 Read Holding Registers
- Address = 10 (Protocol address)
- Quantity = 20
- Scan Rate = 1000 (Then it will poll for data every 1000ms)
3. To change a value just start typing
Note: you can always press F1 for help.
Warning:
-----------------------------
The use of RTS controlled RS232/RS485 converters should be avoided if possible.
It is difficult to determine the exact time when to switch off the transmitter
with non real-time operating systems like Windows and Linux. If it is switched
off to early characters might still sit in the FIFO or the transmit register of
the UART and these characters will be lost. Hence the slave will not recognize
the message. On the other hand if it is switched off too late then the slave's
message is corrupted and the master will not recognize the message.
Modbus Poll overview:
-----------------------------
Modbus Poll is a powerful, easy to use, master simulating
tool. Modbus Poll will run on all 32-bit Windows versions
in use today - Windows 2000, XP and Vista.
With Modbus Poll you can monitor and test your modbus
slave devices. Some of the features:
- Supports Modbus/TCP, RTU and ASCII modes.
- Test Center for modbus slave developers.
- OLE Automation for interfacing with Visual Basic
Excel etc. To interpret and show the modbus data
according to your specific requirements. E.g. edit
data in Excel and then send to your slave!
- Multiple windows for monitoring of multiple
slaves/data areas.
- Monitoring of serial traffic.
- Data logging to a text file readable by MS Excel.
- Multithreated for best performance.
- Print preview etc.
- 10 Display formats.
Press F2 or double click to edit or just start typing a new value.
Order information:
-----------------------------
Visit http://www.modbustools.com
Technical Support:
-----------------------------
Your feedback is very important for the further development
of Modbus Poll. For bug reports, comments, suggestions or
complaints, please find contact information at
http://www.modbustools.com
近期下载者:
相关文件:
收藏者: