diagslave-3.2

所属分类:其他
开发工具:C/C++
文件大小:193KB
下载次数:0
上传日期:2020-01-05 05:20:33
上 传 者Tecnoelectricas
说明:  Cuanto dolor cuanta pena para esta caca

文件列表:
win\diagslave.exe (148992, 2019-04-01)
LICENSE-FREE.txt (4720, 2019-04-01)
LICENSE-FREE.pdf (59422, 2014-02-13)

FieldTalk(TM) diagslave Windows Edition Read Me Notes Revision 3.2, 2019-04-01 This Read Me file contains last-minute product information for the FieldTalk(TM) diagslave utility. diagslave is a command line based Modbus slave simulator and test utility. _________________________________________________________________ Files part of the package README.txt, README.pdf These Read Me notes. LICENSE-FREE.txt, LICENSE-FREE.pdf License containing the Terms & Conditions of use for this free software. win/modpoll.exe Windows binary for Intel x86 architectures (32 and ***-bit) _________________________________________________________________ Usage Usage: diagslave [OPTIONS] [SERIALPORT] Arguments: serialport Serial port when using Modbus ASCII or Modbus RTU protocol COM1, COM2 ... on Windows /dev/ttyS0, /dev/ttyS1 ... on Linux General options: -m ascii Modbus ASCII protocol -m rtu Modbus RTU protocol (default) -m tcp MODBUS/TCP protocol -m udp MODBUS UDP -m enc Encapsulated Modbus RTU over TCP -o # Master activity time-out in seconds (1.0 - 100, 3 s is default) -a # Slave address (1-255 for RTU/ASCII, 0-255 for TCP) Options for MODBUS/TCP: -p # TCP port number (502 is default) -c # Connection time-out in seconds (1.0 - 3600, 60 s is default) Options for Modbus ASCII and Modbus RTU: -b # Baudrate (e.g. 9600, 19200, ...) (19200 is default) -d # Databits (7 or 8 for ASCII protocol, 8 for RTU) -s # Stopbits (1 or 2, 1 is default) -p none No parity -p even Even parity (default) -p odd Odd parity -4 # RS-485 mode, RTS on while transmitting and another # ms after Options for Modbus RTU: -f # Tolerance for inter-frame gap detection in ms (0-20) _________________________________________________________________ Release history Version 3.2 (2019-04-01) * Added -f # option to set tolerance for inter-frame gap detection Version 3.1 (2018-11-28) * Modbus UDP protocol added (-m udp) Version 3.0 (2018-07-09) * RTU over TCP protocol added, which is also known as encapsulated RTU (-m enc) Version 2.13 (2013-05-16) * Bug fix, slave ID of 255 for Modbus/TCP did not work Version 2.12 (2012-07-19) * RTU/ASCII: Added RS-485 mode for Win32, QNX and Linux platforms. * COMn syntax can now also be used for COM port number >= 10 Version 2.11 (2011-03-05) * Protocol is now auto-detected as RTU or TCP depending on value of first parameter Version 2.10 (2010-03-31) * Added connection time-out, changed -t to -o for activity time-out. Version 2.9 (2009-11-16) * Default baudrate is now 19200 as per Modbus standard. Version 2.8 (2009-10-26) * Using the -d and -s command line parameters returned an error message in earlier releases. Version 2.7 (2009-10-20) * First release as standalone application. _________________________________________________________________ Copyright (c) 2002-2019 proconX Pty Ltd. All rights reserved. Please refer to file LICENSE-FREE for license and distribution terms. THIS SOFTWARE IS PROVIDED BY PROCONX AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL PROCONX OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. _________________________________________________________________

近期下载者

相关文件


收藏者