FXGPWIN
所属分类:文章/文档
开发工具:PLC
文件大小:757KB
下载次数:0
上传日期:2020-10-10 16:57:49
上 传 者:
JIMCHINA
说明: 应用于三菱FX系列PLC的应用和开发的编程软件,一般用于T形图编程。
(The programming software applied to the application and development of Mitsubishi FX series PLC is generally used for t-chart programming.)
文件列表:
FXGPWIN\DeIsL1.isu (1897, 2008-05-10)
FXGPWIN\DeIsL2.isu (1835, 2008-06-06)
FXGPWIN\DeIsL3.isu (1835, 2008-08-22)
FXGPWIN\DeIsL4.isu (1835, 2009-08-21)
FXGPWIN\FX2NPP.DLL (58816, 2000-02-26)
FXGPWIN\FXDLL.DLL (55872, 1999-12-14)
FXGPWIN\FXGPWIN.EXE (1383232, 2000-03-24)
FXGPWIN\FXGPWIN.HLP (88847, 1999-01-14)
FXGPWIN\FXPCHK00.DLL (10944, 1997-09-19)
FXGPWIN\FXPP.DLL (53184, 2000-02-29)
FXGPWIN\MODEMDAT.DAT (259, 2000-03-01)
FXGPWIN\SPIN.VBX (22528, 1993-06-24)
FXGPWIN\TMPTOFXW.EXE (218864, 2000-03-16)
FXGPWIN\UNTITL02.COW (264, 2009-12-18)
FXGPWIN\UNTITL02.DMW (16768, 2009-12-18)
FXGPWIN\UNTITL02.PMW (16416, 2009-12-18)
FXGPWIN\UNTITL02.PTW (1394, 2009-12-18)
FXGPWIN (0, 2013-01-10)
-----------------------------------------------------------
Read this manual before using the FX-PCS/WIN-E
April, 2000 Mitsubishi Electric Corporation
-----------------------------------------------------------
- To our customers using the FX-PCS/WIN-E
We appreciate it very much that you have purchased our software product.
By using the FX-PCS/WIN-E software, you can create sequence programs for our FX
Series programmable controller on the Windows3.1,the Windows95 or the Windows***.
You can create programs using three types of programming languages, circuit
diagrams, lists and SFC drawings. You can perform printing using a printer,
monitor operations of programmable controllers, and turn on and off devices for
operating programmable controllers.
Note:
The FX-PCS/WIN-E does not support long file names allowed in the Windows95 and
the Windows***.
The FX-PCS/WIN-E does not assures in the WindowsNT.
- Contents of version upgrade
Contents of upgrade from Ver. 2.10 to Ver. 3.00
1. Set function of transfer speed with PLC.
The transfer speed can be changed in the FX2N and FX1N.
The speed which can be set are 9,600bps or 19,200bps.
2. New to FX1S and FX1N instructions.
Programming which includes new instruction and device which corresponds to
FX1S and FX1N.
Input and display of new instruction and device.
Error check on new instruction and device.
3. Import and export of comment file
Import and export of all individual comment types were enabled.
4. PLC type change.
Destination PLC type is open for all PLC types.
Contents of upgrade from Ver. 2.00 to Ver. 2.10
1. SFC edit
SFC blocks including the INITIAL STATE can be deleted.
The LADDER BLOCK symbol can be deleted.
2. SFC conversion
SFC blocks with an error had been unconditionally deleted.
The alert message "The SFC program has an error. Do you want to complete the
conversion? If "Yes", the error will be deleted. If "No", the conversion is
discontinued." is displayed.
Moreover, the SFC conversion is able to be interrupted.
3. Display switch of SFC/Inner ladder
Short cut (Ctrl+L) is added.
4. Inner ladder of State (STL ladder) edit.
Line insertion in the first step is prohibited.
5. Inner ladder edit
There is a limitation on the instructions which can be input with an Inner
ladder.
The check on this limitation was reinforced.
Contents of upgrade from Ver. 1.20 to Ver. 2.00
1. Creation of new folders (directories)
2. Change of file titles
3. Save of files for which only file names are entered
4. Alert display at termination
5. Save of device comments to the PLC
6. Addition of icons to the tool bar
7. Addition of a confirmation message for device range setting in model change
8. Display of MC contacts
9. Review of the zoom ratio
10. Edition of Ladder
Addition of the cancel function
Addition of diversified key input functions
Addition of the undo function
11. Review of the device comment window
12. Display of current values in Ladder monitor
13. Entry Device monitor
Display of device comments
Mixture of 16bit display and 32bit display on one screen
14. Display of batch transfer with the PLC in the form of progress bar
15. Display of mismatch parameters in collation with the PLC
16. Addition of the automatic scaling function in printing
17. Review of the header/footer print position
18. Printing of device comments in two rows
Contents of upgrade from Ver. 1.10 to Ver. 1.20
1. It is impossible to insert lines in the circuit window by using short-cut-key.
In circuit edit window, the short-cut-key for line deleting (Ctrl + Delete)
does not work.
Add short-cut-key of shift + Insert and shift + Delete.
2. Currently, the cursor doesn't move down automatically at deleting vertical
wire by shift and F8 in puts. The cursor should move down automatically
when the wire is deleted.
3. Improve the monitoring response at Entry device monitor function.
4. The Device Monitor Window does not reflect changes made to a timer or counter
preset.
You must close the window and re-open it to view the updated presets.
Upgrade software.
5. It takes long time to read the comments from the data file.
Reduce the time by improving the read procedure.
6. Menu of Runtime program changes should be disabled while FX0,FX0S is selected.
7. Correct the spelling errors.
8. There are two short-cut-keys which have same name for deferent short cuts.
9. When we delete or insert NOP instruction at the program list window, the coil
and circuit comments are moved to bad position.
Upgrade software.
Contents of upgrade from Ver. 1.00 to Ver. 1.10
1. Ladder display
The thickness of ruler lines on ladder diagrams on the screen and printed
sheets can be changed.
The ruler line thickness setting item is added on the environment setting
dialog offered by the option menu.
2. Comment display
The function is added so that "comment display" contents are saved on the
ladder display window, and that the saved contents are displayed when the
ladder window is displayed at the next time.
3. Writing of programs to programmable controllers
The partial write function in which step Nos. can be arbitrarily specified is
added.
4. Entry device monitor
On the entry device monitor screen, entry devices can be saved in a file.
By reading the saved file, the same devices whose registration was monitored
previously can be used for monitoring.
While the entry device monitor window is active, "Import(I)" and "Export(E)"
are displayed on the file menu (identifier = *.rmw).
5. Sharing of comment data
The comment data created in a different program can be used.
While the comment edit window is active, "Import(I)" and "Export(E)" are
displayed on the file menu.
6. Saving of comment data in the DOS(FX-PCS/AT-EE) format
If there is comment data when a program is saved in the DOS format, the
comment data is automatically saved also in the DOS format.
(Device comments exclusively are saved.)
7. PLC type change
Conventionally, the PLC type was able to be changed from a lower level to an
upper level exclusively. Currently, the PLC type can be changed also from an
upper level to a lower level.
8. Ladder conversion
It can be set whether data is written in the RUN mode when a ladder is
converted.
The setting item is provided on the environment setting dialog offered by the
option menu.
9. Ladder monitor screen
Flickering on the screen is eliminated.
10. Printout speed
The pre-processing time for printout is reviewed.
(Ratio against conventional value: 1/10)
11. Device use list display
The display time is reviewed. (Ratio against conventional value: 1/10)
- Cautions
1. The copyright of this software and this manual belongs to Mitsubishi Electric
Corporation.
2. It is prohibited to copy or duplicate a part or all of this software and this
manual without our permission.
It is prohibited to duplicate this software except duplication for backup.
3. It is prohibited to analyze the main body application, the DLL, etc.
4. The contents of this software and this manual are subject to change without
notice for technical improvements of the product, etc.
5. Though we have taken all possible measures for the contents of the product,
contact our company if you have any questions or find errors, a defective
disc, etc.
6. The company name and the product name are trademark or registered trademark
of the corresponding company.
近期下载者:
相关文件:
收藏者: