FANUC-Fladder-V5.3

所属分类:其他行业
开发工具:Windows_Unix
文件大小:13224KB
下载次数:27
上传日期:2012-10-18 11:55:04
上 传 者diracv
说明:  Fanuc PMC 编程软件 版本号V5.3,用于PMC梯形图控制程序编写、监控、上载下载以及监控,是Fanuc 机床调试的必备软件。
(Fanuc PMC programming software version number V5.3 for PMC ladder control program preparation, monitoring, uploading and downloading, and monitoring Fanuc debugging tools necessary software.)

文件列表:
FANUC Fladder Ⅲ V5.3\AutoRun.inf (55, 2001-12-26)
FANUC Fladder Ⅲ V5.3\CopyFd.bat (1449, 2003-01-07)
FANUC Fladder Ⅲ V5.3\Disk1\data1.cab (592921, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk1\data1.hdr (37607, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk1\data2.cab (159232, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk1\ikernel.ex_ (346602, 2002-07-25)
FANUC Fladder Ⅲ V5.3\Disk1\layout.bin (790, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk1\Setup.exe (54784, 2001-04-11)
FANUC Fladder Ⅲ V5.3\Disk1\Setup.ini (118, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk1\setup.inx (155285, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk2\data3.cab (1304064, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk3\data4.cab (1304064, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk4\data5.cab (1304064, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk5\data6.cab (1304064, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk6\data7.cab (1304064, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk7\data8.cab (1304064, 2006-07-11)
FANUC Fladder Ⅲ V5.3\Disk8\data9.cab (1299621, 2006-07-11)
FANUC Fladder Ⅲ V5.3\FL3AutoRun.exe (217088, 2005-08-25)
FANUC Fladder Ⅲ V5.3\Fl3Autorun.ini (109, 2001-12-26)
FANUC Fladder Ⅲ V5.3\Fl3Autorun.msg (1273, 2006-07-11)
FANUC Fladder Ⅲ V5.3\sn.txt (101, 2006-07-26)
FANUC Fladder Ⅲ V5.3\Tool\APPENDIX\F16&18-M.SYM (19448, 2000-06-12)
FANUC Fladder Ⅲ V5.3\Tool\APPENDIX\F16&18-T.SYM (18920, 2000-06-12)
FANUC Fladder Ⅲ V5.3\Tool\APPENDIX\FS0M-CNV.SYM (7853, 2000-06-12)
FANUC Fladder Ⅲ V5.3\Tool\APPENDIX\FS0T-CNV.SYM (10216, 2000-06-12)
FANUC Fladder Ⅲ V5.3\Tool\APPENDIX\PM-C_CNV.SYM (12376, 2000-06-12)
FANUC Fladder Ⅲ V5.3\Tool\APPENDIX\PM-D.SYM (12008, 2000-06-12)
FANUC Fladder Ⅲ V5.3\Tool\APPENDIX\PM-H.SYM (16258, 2000-06-12)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\ExpandSFC.bat (397, 2003-01-07)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\FL06000.TBL (8168, 2005-09-27)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\FL06100.TBL (8766, 2005-09-27)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\FL08000.TBL (9596, 2005-09-27)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\FlOption.exe (24576, 2005-10-31)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\PSL.bat (387, 2003-01-07)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\SB7CMT2.bat (394, 2003-04-03)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\SB7CMT2SFC.bat (404, 2004-07-13)
FANUC Fladder Ⅲ V5.3\Tool\OPTION\UNINST.bat (414, 2004-12-01)
FANUC Fladder Ⅲ V5.3\Tool\Trace\Trace(J).xls (28672, 2005-05-13)
... ...

README.TXT File README file for FANUC LADDER-III Copyright(C), FANUC LTD., 2000 - 2006. All Rights Reserved. This document provides the information about "FANUC LADDER-III". Please read this document before using the SOFTWARE. ------------------------------------------------------------------------------ [1] Introduction [2] Outline 2.1 FANUC LADDER-III 2.2 Operation environment [3] Activation 3.1 Starting the FANUC LADDER-III from the Windows [Programs] menu. [4] Installation from floppy disk [5] History +-------------------------------------------------------------------------------+ |* Microsoft, MS, MS-DOS are the registered trademarks of Microsoft Corporation.| |* Windows is the trademark of Microsoft Corporation. | |* Other companies, products described in this document are the (registered) | | trademarks of each companies. | +-------------------------------------------------------------------------------+ ============================================================================== [1] Introduction ============================================================================== This manual describes about "FANUC LADDER-III". As for the detailed explanation, refer to the following operator's manual for the FANUC LADDER-III. "FANUC LADDER-III OPERATOR'S MANUAL B-66234EN" Notes (1) All rights regarding "FANUC LADDER-III", including the copyright shall belong to FANUC LTD. (2) No one can use or copy any part or whole of the software or document of "FANUC LADDER-III" without a prior agreement. ============================================================================== [2] Outline ============================================================================== 2.1 FANUC LADDER-III FANUC LADDER-III is a programming system for developing FANUC PMC sequence program. Main functions are shown below. 1) Monitoring of ladder sequence 2) Monitoring of signal status 3) Monitoring of PMC status 4) On-Line editing of ladder diagram 5) Debugging ladder sequence 6) Signal trace 7) Signal analysis 8) Saving and restoring PMC parameter 9) Others(Off-Line editing and printing, etc.) 2.2 Operation environment To use this software, the requirements indicated in the table below must be satisfied. +-------------------+---------------------------------------------------+ | Computer | IBM PC/AT COMPATIBLE | +-------------------+---------------------------------------------------+ | OS | Microsoft Windows *** Second Edition (SE) | | | Microsoft Windows Millennium Edition (Me) | | | Microsoft Windows NT4.0 (Note 1)| | | Microsoft Windows 2000/XP | +-------------------+---------------------------------------------------+ | CPU | Windows *** SE | | | Pentium 133MHz or better | | | Windows Me/NT4.0/2000 | | | Pentium 166MHz or better | | | Windows XP | | | Pentium II 333MHz or better | +-------------------+---------------------------------------------------+ | Memory | Windows *** SE | | | 16MBytes or more(32MBytes recommended) | | | Windows NT4.0 | | | 24MBytes or more(32MBytes recommended) | | | Windows Me/2000 | | | 32MBytes or more(***MBytes recommended) | | | Windows XP | | | ***MBytes or more | +-------------------+---------------------------------------------------+ | Hard disk | 20Mbytes or more free space (Note 2)| +-------------------+---------------------------------------------------+ | Graphic adapter | VGA or higher | +-------------------+---------------------------------------------------+ | Printer | The printers added by the printers settings on | | | Windows. | +-------------------+---------------------------------------------------+ | Japanese language | Input system in conformity with MS-KANJI API | | input system | | +-------------------+---------------------------------------------------+ (Note 1) When using this software under the WindowsNT 4.0, please install the "Service Pack 3" software. Please get this software from Microsoft Corporation. (Note 2) In addition, the space for storing sequence data is required. ============================================================================== [3] Activation ============================================================================== 3.1 Starting the FANUC LADDER-III from the Windows [Programs] menu. [Operation] (1) Click the [Start] button at the Windows***/Me/NT4.0/2000/XP. (2) Click the [Programs] menu of the [Start] menu. (3) Click the [FANUC LADDER-III] folder of the [Programs] menu. (4) Click the "FANUC LADDER-III" of the [FANUC LADDER-III] folder. Activate the FANUC LADDER-III and run. ========================================================================== [4] Installation from floppy disk ========================================================================== The following are explained here. About the installing procedure by the floppy disk that copied the installer from CD-ROM to the floppy disk. [Operation] (1) Insert CD-ROM in CD-ROM drive. (2) Start command prompt, and go to CD-ROM drive. The example. The CD-ROM drive is D drive. +-------------------+ | | |> D: | |> CD \ | | | +-------------------+ (3) Execute CopyFD.bat, and copy the installer to the floppy disk drive. The example. The floppy disk drive is A drive. +-------------------+ | | |> CopyFd.bat A: | | | +-------------------+ (4) Insert the blank floppy disk in the floppy disk drive according to the displayed message. (5) After the copy of the installer is completed, insert DISK1 in the floppy disk drive. And, execute Setup.exe and begin installing. The example. The floppy disk drive is A drive. +-------------------+ | | |> A:\Setup.exe | | | +-------------------+ ========================================================================== [5] History ========================================================================== Edition 5.20 -> 5.30 In Series 30i/31i/32i-A PMC, the Extended PMC Ladder Instruction Function has been supported. The ladder program difference print function has been supported. PMC address map function has been supported. Cross-reference display function of PMC address has been supported. In the print of ladder diagram, the Extended PMC Ladder Instruction Function has been supported and the print format has been improved. Automatic input of unused address function has been supported. The insertion of elements on the Ladder Diagram edit screen has been improved. In ladder diagram edit screen, "Select Function" dialog has been improved. Edition 5.10 -> 5.20 In the ladder editing, the next net may be deleted by the "Undo" operation after a large net is divided into two nets. This problem has been corrected. The "Undefined instruction" error or the application error occurs when the ladder with specific number of symbols is decompiled. This problem has been corrected. Edition 5.00 -> 5.10 The connection/disconnection button of the online communication has been added to the toolbar. The address has been added to the warning message displayed when the compiled symbol/comment includes the characters which can not be used. If the "Update" or the "Restore" button of the online editing screen is clicked when the Search result list screen is opened, the application error sometimes occurs. This problem has been corrected. When the address of function instruction COD/CODB/DISP is replaced by "Replace all" of replacement function, the conversion data table is changed to 0. This problem has been corrected. In Series 30i/31i/32i-A PMC, the double bytes character of the 15th character of the comment may be printed by mistake when the ladder diagram is printed. This problem has been corrected. When there are "02" and "04" after the one byte katakana, those characters are not correctly displayed on the message screen. This problem has been corrected. The data table screen of extra relay is displayed though the setting to "HIDE PMC PARAM" is specified. This problem has been corrected. Edition 4.90 -> 5.00 In Series 30i/31i/32i-A PMC, PMC Memory C(D address: 20,000 bytes and R addresses: 16,000 bytes) has been supported. In Series 30i/31i/32i-A PMC, 100,000 ladder steps have been supported. In Series 30i/31i/32i-A PMC, the maximum capacity of Flash-ROM file has been expanded to 2 MBytes Multiple address replace function has been added. In Trace function of Series 30i/31i/32i-A PMC, the multi-path PMC funcion has been supported. The wheel function of mouse has been supported. The start number of the data table screen and the extra relay screen of PMC parameter was changed to 0. In Series 30i/31i/32i-A PMC, the condition of load/store of the PMC parameter was changed. In Series 30i/31i/32i-A PMC, the application error occurs by the compile of ladder program if some cases of password are set. This problem has been corrected. Edition 4.80 -> 4.90 The setting of PMC address in 2nd path PMC of Series 30i/31i/32i-A to expand up to the same size as the PMC address in 1st path PMC has been supported. When the mnemonic file and the external symbol file are output, the zero suppression function of the PMC address is supported. When the mnemonic file is converted to the source file, the displayed initialization warning message has been improved. When the error occurs by converting the source of the subprogram, warning of "Subprogram (Pxx) was not created" is output to the log file. When the address without the symbol/comment/relay comment appears in the first line of the new pages, the line was not printed in the symbol list. This problem has been modified. Edition 4.70 -> 4.80 - When the extended symbol and comment function was selected for Series 30i/31i/32i-A, the control character of net comment specified in configuration file(%%%FLSET.CNF) was ineffective in source conversion. This problem has been modified. - In Series 30i/31i/32i-A PMC, the data table setting screen for the extra relay has been supported. - The "Cut & Paste" of the ladder diagram between the different models has been supported. - In mnemonic conversion function, each subprogram can be converted into a mnemonic file respectively. - The ladder program difference display function has been supported. - In series 30i/31i/32i-A, loading and storing of multi-language PMC message data have been supported. Edition 4.60 -> 4.70 - In Series 30i/31i/32i-A PMC, the functional instruction PSGNL (SUB50) and PSGN2(SUB63) have been supported - In Series 30i/31i/32i-A PMC, the Compare instructions (21 kinds) of the functional instruction have been supported. - In Series 30i/31i/32i-A PMC, the Output function of the external symbol file has been supported. - The function to easily change the PMC type of ladder program is supported. - In the online monitor display of PMC-SB7, the elapsed time of functional instruction TMR/TMRB displays 0, and it does not increase. This problem has been modified. - In Series 30i/31i/32i-A PMC, the allocation data of I/O Unit-B is not converted to the source file. This problem has been modified. - When the data table of the DISP/COD/CODB instructions have 150 or more data, the program listing will not be displayed correctly if you change the mode to the online. This problem has been modified. - If the ladder is edited when the window of the "Search result list" is displayed, "Run Time Error" sometimes occurs. This problem has been modified. Edition 4.50 -> 4.60 - In Series 30i/31i/32i-A PMC, "Automatic input of timer, counter, rising/falling-edge numbers" has been supported. - In Series 30i/31i/32i-A PMC, "Automatic numbering of TMRB/TMRBF/DIFU/DIFD" has been supported. - In PMC of Extended function for Series 30i/31i/32i-A, "Input of jump label by symbolic name" has been supported. - In series 30i/31i/32i-A PMC, the functional instruction TMRBF (SUB77) has been supported - In the I/O module edit screen of Series 30i/31i/32i-A PMC, /12, /16, /20, /24, /28, and /32 have been added as the allocation name for the connection unit. - In the PMC-PA3/SA1/SA3/SA5/SB3/SB4/SB5/SB6/SB7/SC3/SC4/NB/NB2/NB6/QC, we have added the setting that create the ladder object code which does not contain the coil comment. - In ladder printing of PMC-SB7, SB6, SA1 and so on, the symbol or relay comment of the address of functional instruction parameter is not printed. This problem has been corrected. - In Series 30i/31i/32i-A PMC, If you compile the ladder that used the functional instruction COD and CODB, the error of "I:E-3252 LADDER program is broken." might occur. This problem has been corrected. Edition 4.40 -> 4.50 - The error "J: F-2105: 'RECMP' source program write error." might occur when decompiling the ladder program with special password. This problem has been corrected. Edition 4.30 -> 4.40 - 31i-A PMC and 32i-A PMC has been supported. - In online editing of 30i-A PMC, if you inputted the address of R***-R79 into the parameter of functional instruction, they will be changed into other address such as R16-R31. This problem has been corrected. - In online editing, if the ladder such as nearing limit of F-ROM is edited, the editing ladder is deleted. This problem has been corrected. Edition 4.20 -> 4.30 - In series 30i-A, the functional instruction CS (SUB74), CM (SUB75) and CE (SUB76) have been supported. - In series 30i-A, Multi-language PMC message creation tool has been supported. - In the search function of ladder diagram edit, the setting to search with the address/symbol on cursor was added. - In PMC-SB7 etc., it was corrected that a small letter of the relay comment was converted to a capital letter by the symbol comment edit and the source program conversion. Edition 4.10 -> 4.20 - In series 30i-A, the extended symbol and comment function with the symbol of 40 characters, the comment of 255 characters and 4 paragraphs of comments has been supported. - The Ladder Editting with the symbolic programming has been supported in series 30i-A PMC. - In the first PMC of series 30i-A, the maximum capacity of Flash-ROM has been expanded to 1.5 MBytes. - When the net number or the page number is specified, the ladder diagram cannot be printed. Edition 4.00 -> 4.10 - The online monitor function of mnemonic language has been supported. - The function that the ladder diagram on display outputs as the text file was added. - In the source program conversion, the function for merging the new symbol, the comment and the net comment was added. - Data size described in decimal and the F-ROM size was added in the memory map file. - The setting that outputs or inputs each data file to the same holder as the LAD file was added. - In the online editing mode of online function, it was corrected that if the ladder that cannot display the whole error net on a screen is scrolled or clicked the other windows, it will freeze. - In PMC-SB7, it was corrected that a setting of the Selectable I/O link assignment function of the 2nd channel become null. - When the ladder with many symbols and comments was decompiled, the problem that the processing time was long was corrected. - The following problem in 30i-A PMC was corrected. The address can not be searched, even though the address of the functional instruction parameter by "Replace All" and "Search Result List Display" were specified right. Edition 3.40 -> 4.00 - 30i-A PMC has been supported. - Online ladder editing on display window became possible. - Symbol comment editing screen has been improved. (List display by a signal kind, Cut/Copy/Past by each line, etc) - Duplicate coil check function of ladder program has been added. - The application error occurred when loader board was selected in the RS232C connection. This problem has been corrected. Edition 3.30 -> 3.40 - On Message Data Editing screen, european character has been supported by code input. - On Message View screen, some KANJI(multi-byte) characters were not displayed correctly. This problem has been corrected. - When the source program was compiled in PMC-SB7, the value of the ladder execution in the system parameter was always 150%. This problem has been corrected. Edition 3.20 -> 3.30 - The explanation of the use of the functional instruction has been added in the online help. - The button to display the printer property screen has been added on the printer set screen. - Undo(Ctrl+Z)/Redo(Ctrl+Y) has been supported in LADDER Diagram editor screen. - In the command line execution function, the merging function was added to the import command of the symbol/comment data. - In Windows XP, newline symbol was not displayed in the message data editing screen. This problem has been corrected. - The application error occurs when the LAD file is saved if the USB keyboard is connected with the personal computer. This problem has been corrected. Edition 3.10 -> 3.20 - The name of this software has been renamed to FANUC LADDER-III. (The old name was FAPT LADDER-III) - In a conversion of a mnemonic file to a source program, some character of KATAKANA was not converted correctly in net comments. This problem has been corrected. - In PMC-SB7, the application error occasionally occurred, if the communication b ... ...

近期下载者

相关文件


收藏者