dja

积分:358
上传文件:10
下载次数:344
注册日期:2012-12-22 22:42:58

上传列表
article-Rotor-Field-Oriented-Control-of-Five-Phas - This paper presents an application of rotor field oriented control (RFOC) to a five-phase induction motor with the combined fundamental and third harmonic currents. Based on the motor model developed in a new d,q,d,q,n reference frame, the complete theory and modeling of rotor field oriented control of the five-phase induction motor are established. Specifically, investigation is made to improve power density and output torque of the five-phase induction motor by injecting third harmonic of currents. By the proper dynamical adjustment and steady state compensation, the rotor field oriented control of the five-phase induction motor not only achieves a high drive performance, but also controls the fundamental and third harmonic flux and torque to generate the desired nearly rectangular air-gap flux. Both simulation and experimental results further verify the theoretical analysis and demonstrate the feasibility and practical value of the proposed five-phase induction motor drive.,2014-10-20 14:14:44,下载8次
article-Leila-Parsa.rar - This paper presents the sensorless direct torque control (DTC) technique for five-phase interior permanent magnet (IPM) motors. By using the introduced technique fast torque response with low ripple in the stator flux and torque of the five-phase interior permanent magnet motor can be achieved. Having thirty-two space voltage vectors provides great flexibility in selecting the inverter switching states. Therefore, the stator flux and torque can be more precisely adjusted. Position information and speed are being estimated based on the position of the stator flux linkages. The mathematical model of the fivephase interior permanent magnet motor is first derived. Later, the speed sensorless direct torque control method of the fivephase IPM is introduced. A five phase interior permanent magnet motor and five leg IGBT based inverter were designed and fabricated in the laboratory. The control method is implemented on a TMS320C32 digital signal processor board.,2014-10-20 14:10:23,下载13次
article-Hamid-A.-Toliyat.rar - In this paper, direct torque control (DTC) of fivephase induction motor is developed. A novel DTC scheme is proposed, where fast torque response with low ripple in the stator flux and torque of five-phase induction motor can be achieved. In comparison with DTC for three phase induction motor, the five-phase DTC system has thirty-two space voltage vectors, which provide greater flexibility in selecting the inverter switching states thus accomplishing a more precise control of the stator flux and torque. Simulation and experimental results clearly demonstrate a better dynamic and steady state performance with DTC for five-phase induction motor, which suggest that the combination of DTC with multi-phase induction motor have a great practical prospect in motor drives.,2014-10-20 14:09:00,下载5次
article--Analysis-and-Simulation-of-Five-Phase.ra - In this paper, a dq model based on transformation theory for five-phase induction machines is presented. A detailed implementation of an indirect-type five-phase field-orientation control including the hysteresis-type pulsewidth modulation (PWM) current regulator is described. A method for continuous and disturbance-free operation of a five-phase field-orientedcontrolled induction motor drive with complete loss of one, two, or even three legs of the inverter or motor phases is described. A complete analysis and computer simulation of this control technique is included.,2014-10-20 14:05:13,下载24次
01257704.rar - This paper analyses general active filters that can be applicable to EMI filter, active power filter, etc. It gives generalized equations presenting insertion losses and input impedances of various kinds of active filters, from which the requirements and limitations of active filters can be identified. Based on this analysis, the effectiveness of the active filters presented in several literatures is investigated. With the results of this study, an appropriate topology of an active filter for a specific application can be selected with a good rationale. ,2012-12-22 23:30:38,下载3次
01216591.rar - This paper deals with digital control of a series active filter integrated with a diode rectifier where the series active fdter is controlled to function as a current source. A predictive current regulator is considered for the series ac- tive filter to achieve good ripple characteristics and predictable switching losses. The operating conditions, and the effect thereof on the current regulator are considered and oversam- pling and prediction of the load voltage is suggested to improve the active filtering performance without increasing the switching frequenc,2012-12-22 23:22:29,下载14次
00988679.rar - This paper presents a fully-digital-controlled shunt active filter for harmonic termination of a power distribution system. The main purpose of the active filter based on voltage detection is not to compensate for current harmonics but to damp out harmonic propagation caused by line inductors and shunt capacitors for power factor correction. However, time and phase delays inherent in digital controllers might lead to unsatisfactory harmonic-damping performance although digital controllers are preferable to analog controllers. This paper deals with the design and implementation of a digital controller for a shunt active filter based on voltage detection. Experimental results obtained from a laboratory system developed in this paper verify the viability and effectiveness of the fully-digital-controlled active filter.,2012-12-22 23:19:31,下载25次
00897012.rar - Passive filter and active filter are two ahnative strategi- es to suppress harmonics in the electrical distribution system. Pas- sive filter is dc and efficient but it may cause the resonimce problem. Active film has become a mature tecblogy recently and will considerably be generalized in the near fuhrre. In this paper, a laboratmy which consists of 110 KVA six-pulse rectifier loads, one 50 KVA active filter, and six-step 54 KVAR passive f~ has been monic current sou~ce are mvestigeted by expeaiment and simulation. The passive lilter and active film are applied to dif€ erent harmonic sources by turns and the harmonics aAer compensation are md. It is observed fkom the experiment measurements, application of passive filter or active filter to harmonic voltage source will amp@ the harmonic currents at the load side and larger capacity of filter is needed. ,2012-12-22 23:10:39,下载13次
00759919.rar - his paper presents the analysis of real power system events recorded at a light industrial site to determine the effect of a shunt active filter on power quality. The shunt active fdter is shown to improve power quality by lowering the distodon of the supply voltage in both the transient and steady state. The shunt active filter power rating and other design information are also determined. The performance degradation of the shunt active fdter when it has a limited rating is then demonstrated. In one case the voltage distortion is made worse by the active fdter. The requirements that various transient events, including capacitor switching and induction motor starts, place on the shunt active tilter design ace outlined. These requirements are such that the required switching frequencies exceed those attainable with ICBTs and transient ratings dominate the active fdter design constraints. ,2012-12-22 23:06:36,下载5次
OPEN-SWITCH-FAULTS-DETECTION-AND.rar - This paper proposes an open switch faults detection and localization algorithm for shunt three phase active filter topology. It mainly details converter configuration and examines a simple and reliable optimised fault diagnosis method. The con verter topology is based on classical three-leg active power filter topology. A ne w fault diagnosis method is proposed, based on classical currents measurements. It includes combinatory logic to analyse and validate error signals. A Hysteresis Control is applied before and after fault detection, which avoids any controller reconfiguration. Simulation results obtained with Matlab/Simulink/Plecs tools prove the effectiveness of this method. ,2012-12-22 22:55:12,下载31次

近期下载
solar upqc.rar - Design and Simulation of UPQC to Improve Power Quality and Transfer Power of photovoltaic array to grid
5.rar - Intelligent Islanding and Seamless Reconnection Technique for Micro grid with UPQC
5.Generalized-UPQC-system-with-an-improved.rar - very good excellent amazing
upqcfuzzy1.rar - fuzzy logic controller for upqc

收藏