<html xmlns="http://www.w3.org/1999/xhtml">
<head>
<meta charset="utf-8">
<meta name="generator" content="pdf2htmlEX">
<meta http-equiv="X-UA-Compatible" content="IE=edge,chrome=1">
<link rel="stylesheet" href="https://static.pudn.com/base/css/base.min.css">
<link rel="stylesheet" href="https://static.pudn.com/base/css/fancy.min.css">
<link rel="stylesheet" href="https://static.pudn.com/prod/directory_preview_static/628bd7e216e0ca71414dd4b7/raw.css">
<script src="https://static.pudn.com/base/js/compatibility.min.js"></script>
<script src="https://static.pudn.com/base/js/pdf2htmlEX.min.js"></script>
<script>
try{
pdf2htmlEX.defaultViewer = new pdf2htmlEX.Viewer({});
}catch(e){}
</script>
<title></title>
</head>
<body>
<div id="sidebar" style="display: none">
<div id="outline">
</div>
</div>
<div id="pf1" class="pf w0 h0" data-page-no="1"><div class="pc pc1 w0 h0"><img class="bi x0 y0 w1 h1" alt="" src="https://static.pudn.com/prod/directory_preview_static/628bd7e216e0ca71414dd4b7/bg1.jpg"><div class="c x0 y1 w2 h2"><div class="t m0 x1 h3 y2 ff1 fs0 fc0 sc0 ls0 ws0">E<span class="_ _0"></span>therNet/IP<span class="_ _1"> </span><span class="ff2 sc1">转<span class="_ _1"> </span></span>PROFINET<span class="_ _1"> </span><span class="ff2 sc1">网关连接西门子<span class="_ _1"> </span></span>plc</div><div class="t m0 x2 h4 y3 ff2 fs1 fc0 sc1 ls0 ws0">配置案例</div><div class="t m0 x3 h5 y4 ff3 fs2 fc1 sc0 ls0 ws0">1<span class="ff2">、罗克韦尔(</span>AB<span class="ff2">)</span> PLC 1769-L32E<span class="_ _2"> </span><span class="ff2">以太网通讯(</span>EtherNet/IP<span class="ff2">)与西门子<span class="_ _2"> </span></span>S7-1200 </div><div class="t m0 x4 h5 y5 ff3 fs2 fc1 sc0 ls0 ws0">PLC<span class="ff2">(</span>PROFINET<span class="ff2">)进行连接。今天与大家分享一篇<span class="_ _2"> </span></span>EtherNet/IP<span class="_ _2"> </span><span class="ff2">转<span class="_ _2"> </span></span>PROFINET<span class="_ _2"> </span><span class="ff2">的通讯配置方案。本文主</span></div><div class="t m0 x4 h5 y6 ff2 fs2 fc1 sc0 ls0 ws0">要介绍稳联技术的<span class="_ _2"> </span><span class="ff3">EtherNet/IP<span class="_ _2"> </span></span>转<span class="_ _2"> </span><span class="ff3">PROFINET<span class="_ _2"> </span></span>网关<span class="_ _3"> </span><span class="ff3">WL-ABC2006</span>,连接西门子<span class="_ _2"> </span><span class="ff3">S7-1200 PLC<span class="_ _3"> </span></span>与罗克韦尔</div><div class="t m0 x4 h5 y7 ff2 fs2 fc1 sc0 ls0 ws0">(<span class="ff3">AB</span>)<span class="ff3"> PLC 1769-L32E </span>通讯的配置过程,供大家参考。</div><div class="t m0 x3 h5 y8 ff3 fs2 fc1 sc0 ls0 ws0">2<span class="ff2">、硬件配置:</span></div><div class="t m0 x5 h5 y9 ff2 fs2 fc1 sc0 ls0 ws0">罗克韦尔(<span class="ff3">AB</span>)<span class="ff3">PLC<span class="_ _2"> </span></span>配置:<span class="ff3">1<span class="_ _3"> </span></span>个<span class="_ _2"> </span><span class="ff3">1769-L32E</span>、<span class="ff3">1<span class="_ _2"> </span></span>个电源模块(<span class="ff3">24V<span class="_ _3"> </span></span>供电笔记本<span class="_ _2"> </span><span class="ff3">1<span class="_ _2"> </span></span>台)西门子<span class="_ _3"> </span><span class="ff3">PLC<span class="_ _2"> </span></span>一</div><div class="t m0 x5 h5 ya ff2 fs2 fc1 sc0 ls0 ws0">台(或其他<span class="_ _3"> </span><span class="ff3">PROFINET<span class="_ _2"> </span></span>主站都可以),<span class="ff3">EtherNet/IP<span class="_ _2"> </span></span>转<span class="_ _2"> </span><span class="ff3">PROFINET<span class="_ _2"> </span></span>网关一个,网线<span class="_ _3"> </span><span class="ff3">1<span class="_ _2"> </span></span>根</div><div class="t m0 x5 h5 yb ff2 fs2 fc1 sc0 ls0 ws0">软件配置:<span class="ff3">RSLogix5000</span>、<span class="ff3">Step7/</span>博图</div><div class="t m0 x5 h5 yc ff2 fs2 fc1 sc0 ls0 ws0">详细操作步骤:打开<span class="_ _3"> </span><span class="ff3">RSLogix5000<span class="_ _4"></span></span>,进行硬件组态,首先添加网关的<span class="_ _3"> </span><span class="ff3">EDS<span class="_ _2"> </span></span>文件;</div></div></div><div class="pi" data-data='{"ctm":[1.611850,0.000000,0.000000,1.611850,0.000000,0.000000]}'></div></div>
</body>
</html>